Photoconductive detector based on Lead sulfide FR183
FR183 is used in industrial and ecological supervision equipment.
| Element size, mm |
0,15 x 0,60 |
| Spectral range, µm |
1,7 - 2,4 |
| Detectivity, cm * Hz1/2 * W-1 |
5 * 1010 |
| Responsivity, V/W |
8400 |
Time constant, µsec t= 293 ± 5 Ê t= 213 Ê |
100 500 |
| Resistance, MOhm |
0,02 - 0,15 |
| Operating temperature, Ê |
293 ± 5 |
| Weight, g |
1 |
Photoresistor based on lead sulfide FR202.1
FR202.1 is used in thermic automation and spectrum analysis equipment, fire fighting sensors.
The main advantage of these detectors is exclusively high sensitivity in infrared range, which is reached without cooling. They are widely applied in various fields of science and techniques and in military equipment, including homing head.
| No of elements |
1 |
| Element size, mm |
1,7 õ 1,7 |
| Spectral range, µm |
0,5-3,0 (2,0-2,3) |
| Dark current, ÌÎhm |
0,05-3,0 |
| Detectivity, cm * Hz1/2 * W-1 |
5 * 1010 |
| Responsivity, V/W |
700 |
| Time constant, µsec |
400 |
| Operating voltage, V |
15 |
| Operating temperature range, °Ñ |
-60...+60 |
| Weight, g |
2 |
| Modification |
In hermetic package |
* The size PSE may be determined by customer
Photoconductive detector based on lead sulfide FR220, FR220-01, FR220-02, FR220-03, FR220-04, FR220-05, FR220-06
FR220, FR220-01, FR220-02, FR220-03, FR220-04, FR220-05, FR220-06 are used in thermic automation and spectrum analysis equipment, fire fighting sensors.
The main advantage of these detectors is exclusively high sensitivity in infrared range, which is reached without cooling. They are widely applied in various fields of science and techniques and in military equipment, including homing head.
| Model |
FR-220 |
FR-220-01 |
FR-220-02 |
FR-220-03 |
FR-220-04 |
FR-220-05 |
FR-220-06 |
| No of elements |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| Element size, mm |
10õ10 |
8x8 |
6x6 |
4x4 |
3x3 |
2x2 |
1x1 |
| Spectral range, µm |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
| Peak wavelength (λpeak), µm |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
| Resistance, MOhm |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
| Detectivity, cm * Hz1/2 * W-1 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
| Responsivity, V/W |
2,1 * 104 |
3,1 * 104 |
5,6 * 104 |
1,2 * 105 |
1,1 * 105 |
2,5 * 105 |
9,8 * 105 |
| Time constant, µsec |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
| Operating voltage, V |
100 |
100 |
100 |
100 |
80 |
50 |
30 |
| Weight, g |
0,5 |
0,5 |
0,5 |
0,5 |
0,5 |
0,5 |
0,5 |
Photoconductive detectors based on lead sulfide FR226, FR226-01, FR226-02, FR226-03
FR226, FR226-01, FR226-02 and FR226-03 are intended for application in gas analyzers, measuring sets of moisture content.
The main advantage of these detectors is exclusively high sensitivity in infrared range, which is reached without cooling. They are widely applied in various fields of science and techniques and in military equipment, including homing head.
| Model |
FR226 |
FR226-01 |
FR226-02 |
FR226-03 |
| No of elements |
1 |
1 |
1 |
1 |
| Element size, mm |
3õ3 |
2x2 |
1x1 |
0,5x0,5 |
| Spectral range, µm |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
0,5-3,0 |
| Peak wavelength (λpeak), µm |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
2,0-2,3 |
| Resistance, MOhm |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
0,05-1,5 |
| Detectivity, cm * Hz1/2 * W-1 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
7 * 1010 |
| Responsivity, V/W |
1,9 * 105 |
3,2 * 105 |
8,6 * 105 |
1,7 * 106 |
| Time constant, µsec |
300 |
300 |
300 |
300 |
| Operating voltage, V |
80 |
60 |
40 |
20 |
| Weight, g |
0,5 |
0,5 |
0,5 |
0,5 |
| Modification |
In hermetic package |
In hermetic package |
In hermetic package |
In hermetic package |
Low element photodetectors based on PbS
Multielement photodetectors based on PbSe
Single element cooled photoresistors based on PbS
Single element photoresistors based on PbSe
|