Photoresistors based on lead selenide FR189Ì

FR189Ì is intended for application in small-size thermal imagers.

Photodetector is cooled by 4-cascade thermoelectric cooler (TEC).

The cooling of photodetectors by TEC allows to determine thermostabilisation mode, due to this mode dependence on environment may be eliminated.

No of elements 64
Element size, mm 0,05 õ 0,05
Spectral range, µm 2,0-5,0
Peak wavelength (λpeak), µm 3,8-4,2
Resistance, MOhm 1,0-10,0
Detectivity, cm * Hz1/2 * W-1 6 * 1010
Responsivity, V/W 5 * 105
Time constant, µsec 50
Operating voltage, V 2,5-3,5
Weight, g 200

Photoconductive detectors based on lead selenide FR-164

FR-164 is intended for application in small-size thermal imagers.

Photodetector is cooled by 4- cascade thermoelectric cooler (TEC).

The cooling of photodetectors by TEC allows to determine thermostabilisation mode, due to this mode dependence on environment may be eliminated.

No of elements 48
Element size, mm 0,14õ0,125
Spectral range, µm 1,5-5,0
Peak wavelength (λpeak), µm 3,8-4,2
Resistance, MOhm 1,0-10,0
Detectivity, cm * Hz1/2 * W-1 3 * 1010
Responsivity, V/W 1,3 * 105
Time constant, µsec 50
Operating voltage, V 5
Weight, g 130

Multielement photodetectors based on Lead selenide FUR129L, FUR129L-01

FUR129L and FUR129L-01 are intended for application in portable thermal imagers.

Photodetectors are cooled by 2-cascade thermoelectric cooler (TEC).

The cooling of photodetectors by TEC allows to determine thermostabilisation mode, due to this mode dependence on environment may be eliminated.

Model FUR129Ë FUR129Ë-01
No of elements 64 64
Element size, mm 0,1x0,1 0,1x0,09
Spectral range, µm 1,5-5,0 1,5-5,0
Peak wavelength (λpeak), µm 3,7-4,1 3,7-4,1
Detectivity, cm * Hz1/2 * W-1 2 * 1010 2 * 1010
Responsivity, V/W 1 * 107 1 * 107
Time constant, µsec 25 25
Operating voltage, V 6 6
Preamplifier gain coefficient, % 200 200
Preamplifier pass band, Hz 30-15000 30-15000
TEC current, À 0,9 0,9
Weight, g 180 180

Multielement photodetector based on lead selenide FUR139L

FUR139L is intended for using in thermal imagers, spectrometers, guard and in process control.

No of elements 256
Format 2 õ 128
Element size, mm 0,48 õ 0,1
Spectral range, µm 1,5-5,0
Detectivity, cm * Hz1/2 * W-1 3 * 1010
Responsivity, V/W 1 * 107
Time constant, µsec 0,03
Power consumption, W 8
Dimensions, mm 110 õ 90 õ 25
Weight, g 180

Low element photodetectors based on PbS

Single element cooled photoresistors based on PbS

Single element photoresistors based on PbS

Single element photoresistors based on PbSe